Bentone Gas Burner – BG450
120-550 kW Available in versions up to 550 kW, 2-stage or modulating. When biogas is used, Bentone shall always be contacted. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recommended for over- and under-pressure boilers. Design for easy maintenance. Energy saving.Bentone Gas Burner – BG550
Available in versions up to 628 kW. 2-stage or modulating. Can be obtained for all types of gas. When changing from one type of gas to another only a few components need replacing. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recom-mended for over- and underpressure...Bentone Gas Burner – BG650
Available in versions up to 1125 kW. 2-stage or modulating. Can be obtained for all types of gas. When changing from one type of gas to another only a few components need replacing. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recom-mended for over- and underpressure...Bentone Gas Burner – BG700
Available in versions up to 1650 kW. 2-stage or modulating. Can be obtained for all types of gas. When changing from one type of gas to another only a few components need replacing. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recom-mended for over- and underpressure...Bentone Gas Burner – BG800
Available in versions up to 2400 kW. 2-stage or modulating. Can be obtained for all types of gas. When changing from one type of gas to another only a few components need replacing. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recom-mended for over- and underpressure...Bentone Gas Burner – BG950
Available in versions up to 3200 kW. 2-stage or modulating. Can be obtained for all types of gas. When changing from one type of gas to another only a few components need replacing. Mounted on guide bars. Slow opening solenoid valve. Gas connection left or right. Recom-mended for over- and underpressure...Bentone Gas Burner – BGF1 Series
BFG1 is our smallest gas burner and is developed for smaller boilers for domestic appliances and industrial applications. Capacity: 12,3-102,8 kW BF1 can be used for traditional heating of domestic and commercial buildings including industrial applications and mobile equipment. The burner has small dimensions and a high capacity and parts are easy...Bentone Gas Burner – STG Series
Available in versions up to 144 kW for different types of gas. A compact burner, easy to install. Ducted or conventional air inlet. Designed for easy maintenance. Industry standard components are used. A soft pulsation free start. Wide adjustment range and high efficiency with constant combustion values. Also available in biogas versions. Biogas...Eclipse AH MA
Current Version: 2.2 Type: Nozzle Mixing Number of Sizes: Modular Capacity Range: 1,200,000 Btu/hr/LF 1150 kW/m Turndown: 30:1 Max. Upstream Air Temperature: 450°F, 232°C Max. Downstream Air Temperature: 850°F, 454°C Fuels: Natural Gas, Propane, Butane Typical Applications: Make-up air heating Drying Processes Key Attributes: Robust, Reliable performance. Compact Modular design.Eclipse AirHeat V1
Current Version: 1.3 Type: Nozzle Mixing Number of Sizes: Modular Capacity Range: 1,000,000 (Btu/hr/LF) 961 (kW/m) Turndown: 40:1 Max. Process Temperature: 1500°F, 815°C Fuels: Natural Gas, Propane Typical Applications: Incinerators Dry-off nnd curing ovens Indirect air heating Textile Drying Food Processing/baking Ceramic Drying Key Attributes: Lowest CO emissions. Compact modular design. Robust, reliable performance. Industry Standard.Eclipse Furnnox
Current Version: 1.3 Type:Nozzle Mixing Number of Sizes:5 Capacity Range: 25,000 to 2,000,000 (Btu/hr) 73 to 586 (kW) Turndown:10:1 Max. Process Temperature:2800°F, 1540°C Fuels:Natural Gas,Propane, Butane Typical Applications: Galvanizing Furnaces Slot Type Forge Furnces Heat Treating Furnaces Key Attributes: Low NOx. Robust, Reliable performance Compact, Modular design.Eclipse Immersion Jet
Current Version:2.6 Type:Nozzle Mixing Number of Sizes:5 (2", 3", 4", 6", 8") Capacity Range: 190,000 to 8,000,000 (Btu/hr) 56 to 2344 (kW) Turndown:7:1 minimum Max. Process Temperature:200 - 400°F, 93 - 204°C Fuels:Natural Gas, Propane, Butane Typical Applications: Wash and rinse tanks Dip Tanks Pickling Tanks Spray Washers Deep Fryers Salt Baths Quench Tanks Key Attributes: Up to 80% efficiency.Allows the use of smaller, lower cost tubes.Loading
No Products for load
Showing 13–24 of 45 results